Copper Tube for Medical and Plumbing Application
It would be our pleasure to introduce M/S. Hariom Metal & Tubes an ISO 9001: 2015 Certified Company one of the leading quality manufacturer and supplier of Medical Gas Distribution System & DHP grade copper tubes, copper fittings, electrical wires & cables for air-conditioning & refrigeration, plumbing application, hospital project, government project and many more.
Our strengths are total commitment towards maintaining and fulfilling consistent quality standards, highly innovative, extremely competitive pricing and shortest leads times which give us all confidence in putting up a request for getting associated with your esteemed organization as one of the Medical grade copper tube for using in medical gas distribution system. Generally medical copper tube using in Hospital, Operation Theater, and Oxygen supply room as per material specification standard EN-1057-2010 / EN 13448.
En 13348 Standard | HARIOM | ||||||
Chemical Composition | Copper (Cu) + Silver (Ag) | 99.90% min. | Spectro Analysis as per standard tolerances | ||||
Phosphorous | 0.015% to 0.04% | ||||||
Carbon Content Test | Determining lubricant residue as total carbon content by measuring carbon dioxide generated. | Tested with combustion method as per EN723:2009 | |||||
Tensile / Elongation Test | |||||||
Temper | Tensile | Elongation | Hardness | ||||
As per EN 1773 | Common Term | Strength Mpa min | A % min | (Indicative HV 5) | |||
R220a | anneald+ | 220 | 40 | (40 to 75) | Specifications maintained with help of In houe testing facility (tensile and hardness tester) | ||
R 250 | Half Hard | 250 | 30 | (75 to 100) | |||
R 290 | Hard | 290 | 3 | (min 100) | |||
Drifting Test | Depending on size and temper Mandatory / Agreed Terms | Conical Mandrel @ 450 tube end expanding 300 | |||||
Free From Defect Test | EDDY Current Test for detection of local defects | EDDY Current Test conducted in accordance with EN 1971 | |||||
Cleanliness | Proper Degreasing and End Capped | Our pipes are Degreased as per standard and End caps are affixes | |||||
Nominal Outside | Tolearance Wall Thickness | ||||||
diameter (mm) | Below 1 mm | Above 1 mm | |||||
Below 18+-0.04 | 10% | 13% | |||||
Below 18+-0.06 | 10% | 13% | |||||
Medical Gas Pipeline System Size Range as per EN 13348 / BS EN 1057 Specification |
Sr No | Size in MM | Temper | Weight Per Mtr in Kg. | Weight Per Pcs in Kg. | Nos per Bundle. | |
1 | 10 | 0.7 | Half Hard | 0.186 | 0.57 | 60 |
2 | 10 | 0.8 | Half Hard | 0.210 | 0.64 | 55 |
3 | 12 | 0.7 | Half Hard | 0.220 | 0.67 | 50 |
4 | 12 | 0.8 | Half Hard | 0.250 | 0.76 | 45 |
5 | 15 | 0.7 | Half Hard | 0.280 | 0.85 | 40 |
6 | 15 | 0.8 | Half Hard | 0.320 | 0.98 | 40 |
7 | 15 | 0.9 | Half Hard | 0.360 | 1.10 | 35 |
8 | 22 | 0.8 | Half Hard | 0.480 | 1.46 | 35 |
9 | 22 | 0.9 | Half Hard | 0.540 | 1.65 | 20 |
10 | 28 | 0.9 | Half Hard | 0.700 | 2.14 | 16 |
11 | 35 | 1.2 | Half Hard | 1.160 | 3.54 | 10 |
12 | 42 | 1.2 | Half Hard | 1.400 | 4.27 | 8 |
13 | 54 | 1.2 | Half Hard | 1.800 | 5.49 | 6 |
14 | 54 | 1.6 | Half Hard | 2.400 | 7.32 | 5 |